· 110KW and above power with fuse can not be installed due to the shape structural
problems within the controller, users to install an external delivery.
·The above products are only suitable for electric heating load, the standard
rated power and rated current less than rated value can be selected in the selection.
· Control mode 0-10VDC voltage regulator. Rating current form an overload design
margin of 15%.
HTPR-Ⅱ
Type
Rated power
Rated current
Built-in module
Radiator
Mounting Holes
Dimensions
Fuse Specification
Fuse Installation
K/W
A
mm
mm
A
HTPR-Ⅱ-10KW
10
17.5
MTX55A
F150
170×110
190×110×110
20
Built-in
HTPR-Ⅱ-20KW
20
34.9
MTX90A
F150
170×110
190×110×110
40
Built-in
HTPR-Ⅱ-30KW
30
52.4
MTX140A
F150
170×110
190×110×110
60
Built-in
HTPR-Ⅱ-50KW
50
87.3
MTX220A
F150
170×110
190×110×110
90
Built-in
HTPR-Ⅱ-70KW
70
122.3
MTX260A
F150
170×110
190×110×110
125
Built-in
HTPR-Ⅱ-90KW
90
157.3
MTX320A
F150
170×110
190×110×110
160
Built-in
HTPR-Ⅱ-110KW
110
192.2
MTX400A
F150
170×110
190×110×110
200
Built-in
Explain
· The above products are only suitable for electric heating load, the standard
rated power and rated current less than rated value can be selected in the selection.
· Should the user choose the control mode in order to adjust to the best state
in the factory.